Single Core T2 FLRY

Description

Description

Standards

  • International
    ISO 6722 Class B
  • National
    DIN 72551; DIN 72551

Temperature range: -40℃ to +105℃

 

1. Use

  • For comfort car body, Engine and Transmission.
  • Wire harness of low electric circuits for Automotive.
  • Oil resistance and flame retardant, save wiring space.
  • Single core cable with symmetrical(A), non symmetrical(B) conductor structure and reduced wall thickness.

 

2. Specification :

  • DIN 72551
  • ISO  6722 Class B

 

3. Material

  • Conductor : Annealed stranded copper
  • Insulation : lead free PVC(105℃)

Product list

FLRY-A (symetrical)

Conductor Insulation Thickness Max Overall Diameter Conductor Resistance

 Length  

 Size Stranding Diameter
  mm²  no / mm  mm mm  mm  20°C Ω/km   m
 0.22 7 / 0.21   0.7  0.2  1.2  84.8 1 500 
 0.35 7 / 0.26   0.8  0.2  1.3  52.0 1 000 
 0.5  19 /0.19  1.0  0.22  1.6  37.1 1 000
 0.75  19 / 0.23  1.2  0.24  1.91  24.7 1 000
 1.0  19 / 0.26  1.35  0.24  2.1  18.5 500
 1.5  19 / 0.32  1.7  0.24  2.4  12.7 500
 2.5  19 / 0.41  2.2  0.28  3.0  7.6 500

 

FLRY-B ( non-symetrical)

Conductor Insulation Thickness Max Overall Diameter Conductor Resistance   Length
Size Stranding Diameter
 mm²  no /mm  mm mm  mm  20°C Ω/km   m
0.35   12 / 0.21  0.9  0.2 1.4  52.0  1 000
 0.5  16 / 0.21  1.0  0.22  1.6  37.1 1 000
 0.75  24 / 0.21  1.2  0.24  1.9  24.7 1 000
 1.0  32 / 0.21  1.35  0.24  2.1  18.5 500
 1.5  30 / 0.26  1.7  0.24  2.4  12.7 500
 2.5  50 / 0.26  2.2  0.28  3.0  7.6 300
 4.0  56 /0.31  2.75  0.32  3.7  4.7 300
 6.0  84 / 0.31  3.3  0.32  4.3  3.1 200

 

Characteristics

Characteristics

구조적 특성

구조적 특성

도체 재료
연동선
절연
LF PVC
Stranding element
7x0.26

치수

치수

도체 단면적
- mm²

기계적 특성

기계적 특성

Cable flexibility
Flexible
Mechanical resistance to impacts
Good

사용 특성

사용 특성

Length
- m
Oil resistance
Yes
U.V resistance
Very good
연기밀도
Yes
운용온도, 범위
-45 ... 105 °C

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close