TFR-CVV-AMS 0.6/1kV

Products

TFR-CVV-AMS 2x 1.5

Nexans ref.

  • Number of cores: 2
  • Conductor cross-section: 1.5 mm²
  • Outer Diameter: 12 mm
  • Approximate weight: 165 kg/km

 

TFR-CVV-AMS 2x 2.5mm²

Nexans ref.

  • Number of cores: 2
  • Conductor cross-section: 2.5 mm²
  • Outer Diameter: 13 mm
  • Approximate weight: 200 kg/km

 

TFR-CVV-AMS 2x 4mm²

Nexans ref.

  • Number of cores: 2
  • Conductor cross-section: 4 mm²
  • Outer Diameter: 14.5 mm
  • Approximate weight: 265 kg/km

 

TFR-CVV-AMS 2x 6mm²

Nexans ref.

  • Number of cores: 2
  • Conductor cross-section: 6 mm²
  • Outer Diameter: 16 mm
  • Approximate weight: 320 kg/km

 

TFR-CVV-AMS 2x 10mm²

Nexans ref.

  • Number of cores: 2
  • Conductor cross-section: 10 mm²
  • Outer Diameter: 17.5 mm
  • Approximate weight: 430 kg/km

 

TFR-CVV-AMS 3x 1.5mm²

Nexans ref.

  • Number of cores: 3
  • Conductor cross-section: 1.5 mm²
  • Outer Diameter: 12.5 mm
  • Approximate weight: 195 kg/km

 

TFR-CVV-AMS 3x 2.5mm²

Nexans ref.

  • Number of cores: 3
  • Conductor cross-section: 2.5 mm²
  • Outer Diameter: 13.5 mm
  • Approximate weight: 240 kg/km

 

TFR-CVV-AMS 3x 4mm²

Nexans ref.

  • Number of cores: 3
  • Conductor cross-section: 4 mm²
  • Outer Diameter: 15.5 mm
  • Approximate weight: 330 kg/km

 

TFR-CVV-AMS 3x 6mm²

Nexans ref.

  • Number of cores: 3
  • Conductor cross-section: 6 mm²
  • Outer Diameter: 17 mm
  • Approximate weight: 405 kg/km

 

TFR-CVV-AMS 3x 10mm²

Nexans ref.

  • Number of cores: 3
  • Conductor cross-section: 10 mm²
  • Outer Diameter: 18.5 mm
  • Approximate weight: 260 kg/km

 

TFR-CVV-AMS 4x 1.5mm²

Nexans ref.

  • Number of cores: 4
  • Conductor cross-section: 1.5 mm²
  • Outer Diameter: 13.5 mm
  • Approximate weight: 230 kg/km

 

TFR-CVV-AMS 4x 2.5mm²

Nexans ref.

  • Number of cores: 4
  • Conductor cross-section: 2.5 mm²
  • Outer Diameter: 14.5 mm
  • Approximate weight: 300 kg/km

 

TFR-CVV-AMS 4x 4mm²

Nexans ref.

  • Number of cores: 4
  • Conductor cross-section: 4 mm²
  • Outer Diameter: 16.5 mm
  • Approximate weight: 425 kg/km

 

TFR-CVV-AMS 4x 6mm²

Nexans ref.

  • Number of cores: 4
  • Conductor cross-section: 6 mm²
  • Outer Diameter: 18 mm
  • Approximate weight: 530 kg/km

 

TFR-CVV-AMS 4x 10mm²

Nexans ref.

  • Number of cores: 4
  • Conductor cross-section: 10 mm²
  • Outer Diameter: 20.5 mm
  • Approximate weight: 730 kg/km

 

TFR-CVV-AMS 5x 1.5mm²

Nexans ref.

  • Number of cores: 5
  • Conductor cross-section: 1.5 mm²
  • Outer Diameter: 14.5 mm
  • Approximate weight: 280 kg/km

 

TFR-CVV-AMS 5x 2.5mm²

Nexans ref.

  • Number of cores: 5
  • Conductor cross-section: 2.5 mm²
  • Outer Diameter: 15.5 mm
  • Approximate weight: 340 kg/km

 

TFR-CVV-AMS 5x 4mm²

Nexans ref.

  • Number of cores: 5
  • Conductor cross-section: 4 mm²
  • Outer Diameter: 18 mm
  • Approximate weight: 500 kg/km

 

TFR-CVV-AMS 5x 6mm²

Nexans ref.

  • Number of cores: 5
  • Conductor cross-section: 6 mm²
  • Outer Diameter: 19.5 mm
  • Approximate weight: 630 kg/km

 

TFR-CVV-AMS 5x 10mm²

Nexans ref.

  • Number of cores: 5
  • Conductor cross-section: 10 mm²
  • Outer Diameter: 22.5 mm
  • Approximate weight: 880 kg/km

 

TFR-CVV-AMS 6x 1.5mm²

Nexans ref.

  • Number of cores: 6
  • Conductor cross-section: 1.5 mm²
  • Outer Diameter: 15.5 mm
  • Approximate weight: 320 kg/km

 

TFR-CVV-AMS 6x 2.5mm²

Nexans ref.

  • Number of cores: 6
  • Conductor cross-section: 2.5 mm²
  • Outer Diameter: 16.5 mm
  • Approximate weight: 415 kg/km

 

TFR-CVV-AMS 6x 4mm²

Nexans ref.

  • Number of cores: 6
  • Conductor cross-section: 4 mm²
  • Outer Diameter: 19.5 mm
  • Approximate weight: 580 kg/km

 

TFR-CVV-AMS 6x 6mm²

Nexans ref.

  • Number of cores: 6
  • Conductor cross-section: 6 mm²
  • Outer Diameter: 21.5 mm
  • Approximate weight: 750 kg/km

 

TFR-CVV-AMS 6x 10mm²

Nexans ref.

  • Number of cores: 6
  • Conductor cross-section: 10 mm²
  • Outer Diameter: 24.5 mm
  • Approximate weight: 1050 kg/km

 

TFR-CVV-AMS 7x 1.5mm²

Nexans ref.

  • Number of cores: 7
  • Conductor cross-section: 1.5 mm²
  • Outer Diameter: 15.5 mm
  • Approximate weight: 340 kg/km

 

TFR-CVV-AMS 7x 2.5mm²

Nexans ref.

  • Number of cores: 7
  • Conductor cross-section: 2.5 mm²
  • Outer Diameter: 16.5 mm
  • Approximate weight: 440 kg/km

 

TFR-CVV-AMS 7x 4mm²

Nexans ref.

  • Number of cores: 7
  • Conductor cross-section: 4 mm²
  • Outer Diameter: 19.5 mm
  • Approximate weight: 625 kg/km

 

TFR-CVV-AMS 7x 6mm²

Nexans ref.

  • Number of cores: 7
  • Conductor cross-section: 6 mm²
  • Outer Diameter: 21.5 mm
  • Approximate weight: 810 kg/km

 

TFR-CVV-AMS 7x 10mm²

Nexans ref.

  • Number of cores: 7
  • Conductor cross-section: 10 mm²
  • Outer Diameter: 24.5 mm
  • Approximate weight: 1160 kg/km

 

TFR-CVV-AMS 8x 1.5mm²

Nexans ref.

  • Number of cores: 8
  • Conductor cross-section: 1.5 mm²
  • Outer Diameter: 16.5 mm
  • Approximate weight: 400 kg/km

 

TFR-CVV-AMS 8x 2.5mm²

Nexans ref.

  • Number of cores: 8
  • Conductor cross-section: 2.5 mm²
  • Outer Diameter: 17.5 mm
  • Approximate weight: 500 kg/km

 

TFR-CVV-AMS 8x 4mm²

Nexans ref.

  • Number of cores: 8
  • Conductor cross-section: 4 mm²
  • Outer Diameter: 21.5 mm
  • Approximate weight: 740 kg/km

 

TFR-CVV-AMS 8x 6mm²

Nexans ref.

  • Number of cores: 8
  • Conductor cross-section: 6 mm²
  • Outer Diameter: 23.5 mm
  • Approximate weight: 950 kg/km

 

TFR-CVV-AMS 8x 10mm²

Nexans ref.

  • Number of cores: 8
  • Conductor cross-section: 10 mm²
  • Outer Diameter: 26.5 mm
  • Approximate weight: 1330 kg/km

 

TFR-CVV-AMS 10x 1.5mm²

Nexans ref.

  • Number of cores: 10
  • Conductor cross-section: 1.5 mm²
  • Outer Diameter: 18 mm
  • Approximate weight: 470 kg/km

 

TFR-CVV-AMS 10x 2.5mm²

Nexans ref.

  • Number of cores: 10
  • Conductor cross-section: 2.5 mm²
  • Outer Diameter: 20 mm
  • Approximate weight: 610 kg/km

 

TFR-CVV-AMS 10x 4mm²

Nexans ref.

  • Number of cores: 10
  • Conductor cross-section: 4 mm²
  • Outer Diameter: 24.5 mm
  • Approximate weight: 890 kg/km

 

TFR-CVV-AMS 10x 6mm²

Nexans ref.

  • Number of cores: 10
  • Conductor cross-section: 6 mm²
  • Outer Diameter: 26.5 mm
  • Approximate weight: 1140 kg/km

 

TFR-CVV-AMS 10x 10mm²

Nexans ref.

  • Number of cores: 10
  • Conductor cross-section: 10 mm²
  • Outer Diameter: 30.5 mm
  • Approximate weight: 1640 kg/km

 

TFR-CVV-AMS 12x 1.5mm²

Nexans ref.

  • Number of cores: 12
  • Conductor cross-section: 1.5 mm²
  • Outer Diameter: 18.5 mm
  • Approximate weight: 520 kg/km

 

TFR-CVV-AMS 12x 2.5mm²

Nexans ref.

  • Number of cores: 12
  • Conductor cross-section: 2.5 mm²
  • Outer Diameter: 20.5 mm
  • Approximate weight: 700 kg/km

 

TFR-CVV-AMS 12x 4mm²

Nexans ref.

  • Number of cores: 12
  • Conductor cross-section: 4 mm²
  • Outer Diameter: 25.5 mm
  • Approximate weight: 1030 kg/km

 

TFR-CVV-AMS 12x 6mm²

Nexans ref.

  • Number of cores: 12
  • Conductor cross-section: 6 mm²
  • Outer Diameter: 27.5 mm
  • Approximate weight: 1330 kg/km

 

TFR-CVV-AMS 12x 10mm²

Nexans ref.

  • Number of cores: 12
  • Conductor cross-section: 10 mm²
  • Outer Diameter: 31.5 mm
  • Approximate weight: 1900 kg/km

 

TFR-CVV-AMS 15x 1.5mm²

Nexans ref.

  • Number of cores: 15
  • Conductor cross-section: 1.5 mm²
  • Outer Diameter: 20.5 mm
  • Approximate weight: 640 kg/km

 

TFR-CVV-AMS 15x 2.5mm²

Nexans ref.

  • Number of cores: 15
  • Conductor cross-section: 2.5 mm²
  • Outer Diameter: 22.5 mm
  • Approximate weight: 840 kg/km

 

TFR-CVV-AMS 15x 4mm²

Nexans ref.

  • Number of cores: 15
  • Conductor cross-section: 4 mm²
  • Outer Diameter: 25 mm
  • Approximate weight: 1260 kg/km

 

TFR-CVV-AMS 15x 6mm²

Nexans ref.

  • Number of cores: 15
  • Conductor cross-section: 6 mm²
  • Outer Diameter: 29.5 mm
  • Approximate weight: 1630 kg/km

 

TFR-CVV-AMS 20x 1.5mm²

Nexans ref.

  • Number of cores: 20
  • Conductor cross-section: 1.5 mm²
  • Outer Diameter: 22 mm
  • Approximate weight: 830 kg/km

 

TFR-CVV-AMS 20x 2.5mm²

Nexans ref.

  • Number of cores: 20
  • Conductor cross-section: 2.5 mm²
  • Outer Diameter: 25 mm
  • Approximate weight: 1080 kg/km

 

TFR-CVV-AMS 20x 4mm²

Nexans ref.

  • Number of cores: 20
  • Conductor cross-section: 4 mm²
  • Outer Diameter: 30 mm
  • Approximate weight: 1630 kg/km

 

TFR-CVV-AMS 20x 6mm²

Nexans ref.

  • Number of cores: 20
  • Conductor cross-section: 6 mm²
  • Outer Diameter: 33 mm
  • Approximate weight: 2150 kg/km

 

TFR-CVV-AMS 30x 1.5mm²

Nexans ref.

  • Number of cores: 30
  • Conductor cross-section: 1.5 mm²
  • Outer Diameter: 26 mm
  • Approximate weight: 1160 kg/km

 

TFR-CVV-AMS 30x 2.5mm²

Nexans ref.

  • Number of cores: 30
  • Conductor cross-section: 2.5 mm²
  • Outer Diameter: 29 mm
  • Approximate weight: 1540 kg/km

 

TFR-CVV-AMS 30x 4mm²

Nexans ref.

  • Number of cores: 30
  • Conductor cross-section: 4 mm²
  • Outer Diameter: 36 mm
  • Approximate weight: 2385 kg/km

 

Description

Description

Standards

  • National
    KS C IEC 60502-1; KWS 411

Application

Mylar tape shielded control cable for control circuit in the residential and commercial building.
The flame retardant cable for tray conformed to the standard (for technique of electrical equipment)

 

Standard

K 60502-1

KWS 411: 6/10kV Flame retardant control cable

 

Construction

1. Conductor: Stranded annealed round plain copper, Class 2

2. Insulation: PVC, operating temperature 70°C.

3. Shield: Mylar tape shielded with the drain wire

4. Unit: Cabling circular insulated solid wire in case of more 3 cores

7. Outer sheath: Black Flame retardant PVC (TFR PVC)

 

Colors

2 core : Black, White
3 cores: Black, White, Red
4 cores: Black, White, Red, Green
more 5 cores, Numbering on black or red core. The others are white

TFR-CVV-AMS 0.6/1kV design

##image:56058##

Conductor

Insulation

Filler

PS tape

Shield (AL, Mylar)

Outer sheath (TFR PVC)

Drain wire

 

The values of insulation resistance is not defined but only constant number of insulation resistance is defined.
(K=min. 36.7MΩ.km at room temperature, min. 0.037MΩ.km at 70℃)   

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Plain annealed copper
Type of conductor
Stranded, round, class 2
Insulation
PVC
Screen
Mylar tape
Outer sheath
Flame retardant PVC

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
6/10 kV
Test voltage
3500 V

Usage characteristics

Usage characteristics

Operating temperature, range
-15 ... 60 °C
Flame retardant
KSC IEC 60332-3
Bending factor when installed
12 (xD)

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close