TFR-CVV 0.6/1kV
TFR-CVV 0.6/1kV
Control Crosslinked Polyethylene Insulated PVC Sheathed cable
0.6/1kV
TFR-CVV 2x1.5mm²
Nexans ref. 84002882
- Number of cores: 2
- Conductor cross-section: 1.5 mm²
- Outer Diameter: 11 mm
- Approximate weight: 145 kg/km
TFR-CVV 2x2,5mm²
Nexans ref. 84002931
- Number of cores: 2
- Conductor cross-section: 2.5 mm²
- Outer Diameter: 12 mm
- Approximate weight: 200 kg/km
TFR-CVV 2x4mm²
Nexans ref. 84006651
- Number of cores: 2
- Conductor cross-section: 4 mm²
- Outer Diameter: 14 mm
- Approximate weight: 255 kg/km
TFR-CVV 2x6mm²
Nexans ref.
- Number of cores: 2
- Conductor cross-section: 6 mm²
- Outer Diameter: 15 mm
- Approximate weight: 320 kg/km
TFR-CVV 2x10mm²
Nexans ref.
- Number of cores: 2
- Conductor cross-section: 10 mm²
- Outer Diameter: 17 mm
- Approximate weight: 430 kg/km
TFR-CVV 3x1.5mm²
Nexans ref. 84002883
- Number of cores: 3
- Conductor cross-section: 1.5 mm²
- Outer Diameter: 11.5 mm
- Approximate weight: 190 kg/km
TFR-CVV 3x2,5mm²
Nexans ref. 84004219
- Number of cores: 3
- Conductor cross-section: 2.5 mm²
- Outer Diameter: 12.5 mm
- Approximate weight: 240 kg/km
TFR-CVV 3x4mm²
Nexans ref.
- Number of cores: 3
- Conductor cross-section: 4 mm²
- Outer Diameter: 14.5 mm
- Approximate weight: 330 kg/km
TFR-CVV 3x6mm²
Nexans ref.
- Number of cores: 3
- Conductor cross-section: 6 mm²
- Outer Diameter: 16 mm
- Approximate weight: 420 kg/km
TFR-CVV 3x10mm²
Nexans ref.
- Number of cores: 3
- Conductor cross-section: 10 mm²
- Outer Diameter: 18 mm
- Approximate weight: 560 kg/km
TFR-CVV 4x1.5mm²
Nexans ref. 84002885
- Number of cores: 4
- Conductor cross-section: 1.5 mm²
- Outer Diameter: 12.5 mm
- Approximate weight: 230 kg/km
TFR-CVV 4x2,5mm²
Nexans ref. 84002893
- Number of cores: 4
- Conductor cross-section: 2.5 mm²
- Outer Diameter: 13.5 mm
- Approximate weight: 275 kg/km
TFR-CVV 4x4mm²
Nexans ref.
- Number of cores: 4
- Conductor cross-section: 4 mm²
- Outer Diameter: 16 mm
- Approximate weight: 390 kg/km
TFR-CVV 4x6mm²
Nexans ref.
- Number of cores: 4
- Conductor cross-section: 6 mm²
- Outer Diameter: 17 mm
- Approximate weight: 510 kg/km
TFR-CVV 4x10mm²
Nexans ref.
- Number of cores: 4
- Conductor cross-section: 10 mm²
- Outer Diameter: 19.5 mm
- Approximate weight: 720 kg/km
TFR-CVV 5x1.5mm²
Nexans ref. 84002888
- Number of cores: 5
- Conductor cross-section: 1.5 mm²
- Outer Diameter: 13.5 mm
- Approximate weight: 260 kg/km
TFR-CVV 5x2,5mm²
Nexans ref. 84002361
- Number of cores: 5
- Conductor cross-section: 2.5 mm²
- Outer Diameter: 14.5 mm
- Approximate weight: 340 kg/km
TFR-CVV 5x4mm²
Nexans ref.
- Number of cores: 5
- Conductor cross-section: 4 mm²
- Outer Diameter: 17 mm
- Approximate weight: 500 kg/km
TFR-CVV 5x6mm²
Nexans ref.
- Number of cores: 5
- Conductor cross-section: 6 mm²
- Outer Diameter: 18.5 mm
- Approximate weight: 625 kg/km
TFR-CVV 5x10mm²
Nexans ref.
- Number of cores: 5
- Conductor cross-section: 10 mm²
- Outer Diameter: 21 mm
- Approximate weight: 880 kg/km
TFR-CVV 6x1.5mm²
Nexans ref.
- Number of cores: 6
- Conductor cross-section: 1.5 mm²
- Outer Diameter: 14.5 mm
- Approximate weight: 320 kg/km
TFR-CVV 6x2,5mm²
Nexans ref.
- Number of cores: 6
- Conductor cross-section: 2.5 mm²
- Outer Diameter: 15.5 mm
- Approximate weight: 400 kg/km
TFR-CVV 6x4mm²
Nexans ref.
- Number of cores: 6
- Conductor cross-section: 4 mm²
- Outer Diameter: 18.5 mm
- Approximate weight: 575 kg/km
TFR-CVV 6x6mm²
Nexans ref.
- Number of cores: 6
- Conductor cross-section: 6 mm²
- Outer Diameter: 21 mm
- Approximate weight: 730 kg/km
TFR-CVV 6x10mm²
Nexans ref.
- Number of cores: 6
- Conductor cross-section: 10 mm²
- Outer Diameter: 23 mm
- Approximate weight: 1035 kg/km
TFR-CVV 7x1.5mm²
Nexans ref.
- Number of cores: 7
- Conductor cross-section: 1.5 mm²
- Outer Diameter: 14.5 mm
- Approximate weight: 330 kg/km
TFR-CVV 7x2,5mm²
Nexans ref.
- Number of cores: 7
- Conductor cross-section: 2.5 mm²
- Outer Diameter: 15.5 mm
- Approximate weight: 415 kg/km
TFR-CVV 7x4mm²
Nexans ref.
- Number of cores: 7
- Conductor cross-section: 4 mm²
- Outer Diameter: 18.5 mm
- Approximate weight: 610 kg/km
TFR-CVV 7x6mm²
Nexans ref.
- Number of cores: 7
- Conductor cross-section: 6 mm²
- Outer Diameter: 21 mm
- Approximate weight: 780 kg/km
TFR-CVV 7x10mm²
Nexans ref.
- Number of cores: 7
- Conductor cross-section: 10 mm²
- Outer Diameter: 23 mm
- Approximate weight: 1160 kg/km
TFR-CVV 8x1.5mm²
Nexans ref.
- Number of cores: 8
- Conductor cross-section: 1.5 mm²
- Outer Diameter: 15.5 mm
- Approximate weight: 380 kg/km
TFR-CVV 8x2,5mm²
Nexans ref.
- Number of cores: 8
- Conductor cross-section: 2.5 mm²
- Outer Diameter: 16.5 mm
- Approximate weight: 500 kg/km
TFR-CVV 8x4mm²
Nexans ref.
- Number of cores: 8
- Conductor cross-section: 4 mm²
- Outer Diameter: 20 mm
- Approximate weight: 735 kg/km
TFR-CVV 8x6mm²
Nexans ref.
- Number of cores: 8
- Conductor cross-section: 6 mm²
- Outer Diameter: 22 mm
- Approximate weight: 930 kg/km
TFR-CVV 8x10mm²
Nexans ref.
- Number of cores: 8
- Conductor cross-section: 10 mm²
- Outer Diameter: 25 mm
- Approximate weight: 1325 kg/km
TFR-CVV 10x1.5mm²
Nexans ref.
- Number of cores: 10
- Conductor cross-section: 1.5 mm²
- Outer Diameter: 18 mm
- Approximate weight: 460 kg/km
TFR-CVV 10x2,5mm²
Nexans ref.
- Number of cores: 10
- Conductor cross-section: 2.5 mm²
- Outer Diameter: 19.5 mm
- Approximate weight: 580 kg/km
TFR-CVV 10x4mm²
Nexans ref.
- Number of cores: 10
- Conductor cross-section: 4 mm²
- Outer Diameter: 23 mm
- Approximate weight: 890 kg/km
TFR-CVV 10x6mm²
Nexans ref.
- Number of cores: 10
- Conductor cross-section: 6 mm²
- Outer Diameter: 26 mm
- Approximate weight: 1150 kg/km
TFR-CVV 10x10mm²
Nexans ref.
- Number of cores: 10
- Conductor cross-section: 10 mm²
- Outer Diameter: 29 mm
- Approximate weight: 1630 kg/km
TFR-CVV 12x1.5mm²
Nexans ref.
- Number of cores: 12
- Conductor cross-section: 1.5 mm²
- Outer Diameter: 18.5 mm
- Approximate weight: 525 kg/km
TFR-CVV 12x2,5mm²
Nexans ref.
- Number of cores: 12
- Conductor cross-section: 2.5 mm²
- Outer Diameter: 20 mm
- Approximate weight: 690 kg/km
TFR-CVV 12x4mm²
Nexans ref.
- Number of cores: 12
- Conductor cross-section: 4 mm²
- Outer Diameter: 24 mm
- Approximate weight: 1035 kg/km
TFR-CVV 12x6mm²
Nexans ref.
- Number of cores: 12
- Conductor cross-section: 6 mm²
- Outer Diameter: 27 mm
- Approximate weight: 1330 kg/km
TFR-CVV 12x10mm²
Nexans ref.
- Number of cores: 12
- Conductor cross-section: 10 mm²
- Outer Diameter: 30 mm
- Approximate weight: 1900 kg/km
TFR-CVV 15x1.5mm²
Nexans ref.
- Number of cores: 15
- Conductor cross-section: 1.5 mm²
- Outer Diameter: 19.5 mm
- Approximate weight: 630 kg/km
TFR-CVV 15x2,5mm²
Nexans ref.
- Number of cores: 15
- Conductor cross-section: 2.5 mm²
- Outer Diameter: 22 mm
- Approximate weight: 830 kg/km
TFR-CVV 15x4mm²
Nexans ref.
- Number of cores: 15
- Conductor cross-section: 4 mm²
- Outer Diameter: 26 mm
- Approximate weight: 1250 kg/km
TFR-CVV 15x6mm²
Nexans ref.
- Number of cores: 15
- Conductor cross-section: 6 mm²
- Outer Diameter: 29 mm
- Approximate weight: 1625 kg/km
TFR-CVV 20x1.5mm²
Nexans ref.
- Number of cores: 20
- Conductor cross-section: 1.5 mm²
- Outer Diameter: 22 mm
- Approximate weight: 800 kg/km
TFR-CVV 20x2,5mm²
Nexans ref.
- Number of cores: 20
- Conductor cross-section: 2.5 mm²
- Outer Diameter: 24 mm
- Approximate weight: 1060 kg/km
TFR-CVV 20x4mm²
Nexans ref.
- Number of cores: 20
- Conductor cross-section: 4 mm²
- Outer Diameter: 29 mm
- Approximate weight: 1610 kg/km
TFR-CVV 20x6mm²
Nexans ref.
- Number of cores: 20
- Conductor cross-section: 6 mm²
- Outer Diameter: 32 mm
- Approximate weight: 2105 kg/km
TFR-CVV 30x1.5mm²
Nexans ref.
- Number of cores: 30
- Conductor cross-section: 1.5 mm²
- Outer Diameter: 26 mm
- Approximate weight: 1160 kg/km
TFR-CVV 30x2,5mm²
Nexans ref.
- Number of cores: 30
- Conductor cross-section: 2.5 mm²
- Outer Diameter: 28 mm
- Approximate weight: 1540 kg/km
TFR-CVV 30x4mm²
Nexans ref.
- Number of cores: 30
- Conductor cross-section: 4 mm²
- Outer Diameter: 35 mm
- Approximate weight: 2360 kg/km
Description
Description
Standards
-
NationalKS C IEC 60502-1; KWS 411
Application
Power cable for residential, commercial building and distribution circuit.
The flame retardant cable for tray conformed to the standard of technique of electrical equipment.
Construction
1. Conductor: Stranded annealed round plain copper, Class 2
2. Insulation: PVC, operating temperature 70°C.
3. Unit: Cabling circularly insulated solid wire in case of more than 2 cores
4. Outer sheath: Black flame retardant black PVC (TFR PVC)
Colors
2 cores: White /Black
3 cores: White / Black /Red,
4 cores: White / Black / Red / Green
More 5 cores: Numbering on black or red core. The others are white
Certification
KETI
KWS (Collective standard)
TFR-CVV 0.6/1kV design
| ##image:55999## |
Insulation Filler Binder tape Outer sheath (TPR PVC)
|
The values of insulation resistance is not defined but only constant number of insulation resistance is defined
(K=min. 36.7MΩ.km at room temperature, min. 0.037MΩ.km at 70℃)
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Electrical characteristics
Electrical characteristics
Usage characteristics
Usage characteristics
Fire safety characteristics
Fire safety characteristics
Resources
Resources
Current capacity table PVC insulation multicore single phase
PVC insulation/two loaded conductors, copper or aluminium –
Conductor temperature: 70 °C, ambient temperature: 30 °C in air, 20 °C in ground
| Conductor cross-section |
|
|
|
|
|
|
|
|||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| mm² | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al |
| 1.5 | 14.5 | 0.0 | 14.0 | 0.0 | 16.5 | 0.0 | 19.5 | 0.0 | 22.0 | 0.0 | 22.0 | 0.0 | 22.0 | 0.0 |
| 2.5 | 19.5 | 15.0 | 18.5 | 14.5 | 23.0 | 17.5 | 27.0 | 21.0 | 29.0 | 22.0 | 28.0 | 0.0 | 30.0 | 23.0 |
| 4.0 | 26.0 | 20.0 | 25.0 | 19.5 | 30.0 | 24.0 | 36.0 | 28.0 | 37.0 | 29.0 | 38.0 | 0.0 | 40.0 | 31.0 |
| 6.0 | 34.0 | 26.0 | 32.0 | 25.0 | 38.0 | 30.0 | 46.0 | 36.0 | 46.0 | 36.0 | 48.0 | 0.0 | 51.0 | 39.0 |
| 10.0 | 46.0 | 36.0 | 43.0 | 33.0 | 52.0 | 41.0 | 63.0 | 49.0 | 60.0 | 47.0 | 64.0 | 0.0 | 70.0 | 54.0 |
| 16.0 | 61.0 | 48.0 | 57.0 | 44.0 | 69.0 | 54.0 | 85.0 | 66.0 | 78.0 | 61.0 | 83.0 | 63.0 | 94.0 | 73.0 |
| 25.0 | 80.0 | 63.0 | 75.0 | 58.0 | 90.0 | 71.0 | 112.0 | 83.0 | 99.0 | 77.0 | 110.0 | 82.0 | 119.0 | 89.0 |
| 35.0 | 99.0 | 77.0 | 92.0 | 71.0 | 111.0 | 86.0 | 138.0 | 103.0 | 119.0 | 93.0 | 132.0 | 98.0 | 148.0 | 111.0 |
| 50.0 | 119.0 | 93.0 | 110.0 | 86.0 | 133.0 | 104.0 | 168.0 | 125.0 | 140.0 | 109.0 | 156.0 | 117.0 | 180.0 | 135.0 |
| 70.0 | 151.0 | 118.0 | 139.0 | 108.0 | 168.0 | 131.0 | 213.0 | 160.0 | 173.0 | 135.0 | 192.0 | 145.0 | 232.0 | 173.0 |
| 95.0 | 182.0 | 142.0 | 167.0 | 130.0 | 201.0 | 157.0 | 258.0 | 195.0 | 204.0 | 159.0 | 230.0 | 173.0 | 282.0 | 210.0 |
| 120.0 | 210.0 | 164.0 | 192.0 | 150.0 | 232.0 | 181.0 | 299.0 | 226.0 | 231.0 | 180.0 | 261.0 | 200.0 | 328.0 | 244.0 |
| 150.0 | 240.0 | 189.0 | 219.0 | 172.0 | 258.0 | 201.0 | 344.0 | 261.0 | 261.0 | 204.0 | 293.0 | 224.0 | 379.0 | 282.0 |
| 185.0 | 273.0 | 215.0 | 248.0 | 195.0 | 294.0 | 230.0 | 392.0 | 298.0 | 292.0 | 228.0 | 331.0 | 255.0 | 434.0 | 322.0 |
| 240.0 | 321.0 | 252.0 | 291.0 | 229.0 | 344.0 | 269.0 | 461.0 | 352.0 | 336.0 | 262.0 | 382.0 | 298.0 | 514.0 | 380.0 |
| 300.0 | 367.0 | 289.0 | 334.0 | 263.0 | 394.0 | 308.0 | 530.0 | 406.0 | 379.0 | 296.0 | 427.0 | 336.0 | 593.0 | 439.0 |
| A1 Insulated conductors in conduit in a thermally insulated wall |
| A2 Multi-core cable in conduit in a thermally insulated wall |
| B2 Multi-core cable in conduit on a wooden wall |
| C Single-core or multi-core cable on a wooden wall |
| D1 Multi-core cable in ducts in the ground |
| D2 Multi-core cables designed to be buried directly in the ground |
| E Multi-core cable in free air |
Current capacity table PVC insulation multicore three phase
PVC insulation, three loaded conductors/copper or aluminium –
Conductor temperature: 70 °C, ambient temperature: 30 °C in air, 20 °C in ground
| Conductor cross-section |
|
|
|
|
|
|
|
|||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| mm² | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al |
| 1.5 | 13.5 | 0.0 | 13.0 | 0.0 | 15.0 | 0.0 | 17.5 | 0.0 | 18.0 | 0.0 | 19.0 | 0.0 | 18.5 | 0.0 |
| 2.5 | 18.0 | 14.0 | 17.5 | 13.5 | 20.0 | 15.5 | 24.0 | 18.5 | 24.0 | 18.5 | 24.0 | 0.0 | 25.0 | 19.5 |
| 4.0 | 24.0 | 18.5 | 23.0 | 17.5 | 27.0 | 21.0 | 32.0 | 25.0 | 30.0 | 24.0 | 33.0 | 0.0 | 34.0 | 26.0 |
| 6.0 | 31.0 | 24.0 | 29.0 | 23.0 | 34.0 | 27.0 | 41.0 | 32.0 | 38.0 | 30.0 | 41.0 | 0.0 | 43.0 | 33.0 |
| 10.0 | 42.0 | 32.0 | 39.0 | 31.0 | 46.0 | 36.0 | 57.0 | 44.0 | 50.0 | 39.0 | 54.0 | 0.0 | 60.0 | 46.0 |
| 16.0 | 56.0 | 43.0 | 52.0 | 41.0 | 62.0 | 48.0 | 76.0 | 59.0 | 64.0 | 50.0 | 70.0 | 53.0 | 80.0 | 61.0 |
| 25.0 | 73.0 | 57.0 | 68.0 | 53.0 | 80.0 | 62.0 | 96.0 | 73.0 | 82.0 | 64.0 | 92.0 | 69.0 | 101.0 | 78.0 |
| 35.0 | 89.0 | 70.0 | 83.0 | 65.0 | 99.0 | 77.0 | 119.0 | 90.0 | 98.0 | 77.0 | 110.0 | 83.0 | 126.0 | 96.0 |
| 50.0 | 108.0 | 84.0 | 99.0 | 78.0 | 118.0 | 92.0 | 144.0 | 110.0 | 116.0 | 91.0 | 130.0 | 99.0 | 153.0 | 117.0 |
| 70.0 | 136.0 | 107.0 | 125.0 | 98.0 | 149.0 | 116.0 | 184.0 | 140.0 | 143.0 | 112.0 | 162.0 | 122.0 | 196.0 | 150.0 |
| 95.0 | 164.0 | 129.0 | 150.0 | 118.0 | 179.0 | 139.0 | 223.0 | 170.0 | 169.0 | 132.0 | 193.0 | 148.0 | 238.0 | 183.0 |
| 120.0 | 188.0 | 149.0 | 172.0 | 135.0 | 206.0 | 160.0 | 259.0 | 197.0 | 192.0 | 150.0 | 220.0 | 169.0 | 276.0 | 212.0 |
| 150.0 | 216.0 | 170.0 | 196.0 | 155.0 | 225.0 | 176.0 | 299.0 | 227.0 | 217.0 | 169.0 | 246.0 | 189.0 | 319.0 | 245.0 |
| 185.0 | 245.0 | 194.0 | 223.0 | 176.0 | 255.0 | 199.0 | 341.0 | 259.0 | 243.0 | 190.0 | 278.0 | 214.0 | 364.0 | 280.0 |
| 240.0 | 286.0 | 227.0 | 261.0 | 207.0 | 297.0 | 232.0 | 403.0 | 305.0 | 280.0 | 218.0 | 320.0 | 250.0 | 430.0 | 330.0 |
| 300.0 | 328.0 | 261.0 | 298.0 | 237.0 | 339.0 | 265.0 | 464.0 | 351.0 | 316.0 | 247.0 | 359.0 | 282.0 | 497.0 | 381.0 |
| A1 Insulated conductors in conduit in a thermally insulated wall |
| A2 Multi-core cable in conduit in a thermally insulated wall |
| B2 Multi-core cable in conduit on a wooden wall |
| C Single-core or multi-core cable on a wooden wall |
| D1 Multi-core cable in ducts in the ground |
| D2 Multi-core cables designed to be buried directly in the ground |
| E Multi-core cable in free air |
Current capacity table PVC insulation single core single phase
PVC insulation/two loaded conductors, copper or aluminium –
Conductor temperature: 70 °C, ambient temperature: 30 °C in air, 20 °C in ground
| Conductor cross-section |
|
|
|
|
|
|
||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| mm² | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al |
| 1.5 | 14.5 | 0.0 | 17.5 | 0.0 | 19.5 | 0.0 | 22.0 | 0.0 | 22.0 | 0.0 | 0.0 | 0.0 |
| 2.5 | 19.5 | 15.0 | 24.0 | 18.5 | 27.0 | 21.0 | 29.0 | 22.0 | 28.0 | 0.0 | 0.0 | 0.0 |
| 4.0 | 26.0 | 20.0 | 32.0 | 25.0 | 36.0 | 28.0 | 37.0 | 29.0 | 38.0 | 0.0 | 0.0 | 0.0 |
| 6.0 | 34.0 | 26.0 | 41.0 | 32.0 | 46.0 | 36.0 | 46.0 | 36.0 | 48.0 | 0.0 | 0.0 | 0.0 |
| 10.0 | 46.0 | 36.0 | 57.0 | 44.0 | 63.0 | 49.0 | 60.0 | 47.0 | 64.0 | 0.0 | 0.0 | 0.0 |
| 16.0 | 61.0 | 48.0 | 76.0 | 60.0 | 85.0 | 66.0 | 78.0 | 61.0 | 83.0 | 63.0 | 0.0 | 0.0 |
| 25.0 | 80.0 | 63.0 | 101.0 | 79.0 | 112.0 | 83.0 | 99.0 | 77.0 | 110.0 | 82.0 | 131.0 | 98.0 |
| 35.0 | 99.0 | 77.0 | 125.0 | 97.0 | 138.0 | 103.0 | 119.0 | 93.0 | 132.0 | 98.0 | 162.0 | 122.0 |
| 50.0 | 119.0 | 93.0 | 151.0 | 118.0 | 168.0 | 125.0 | 140.0 | 109.0 | 156.0 | 117.0 | 196.0 | 149.0 |
| 70.0 | 151.0 | 118.0 | 192.0 | 150.0 | 213.0 | 160.0 | 173.0 | 135.0 | 192.0 | 145.0 | 251.0 | 192.0 |
| 95.0 | 182.0 | 142.0 | 232.0 | 181.0 | 258.0 | 195.0 | 204.0 | 159.0 | 230.0 | 173.0 | 304.0 | 235.0 |
| 120.0 | 210.0 | 164.0 | 269.0 | 210.0 | 299.0 | 226.0 | 231.0 | 180.0 | 261.0 | 200.0 | 352.0 | 273.0 |
| 150.0 | 240.0 | 189.0 | 300.0 | 234.0 | 344.0 | 261.0 | 261.0 | 204.0 | 293.0 | 224.0 | 406.0 | 316.0 |
| 185.0 | 273.0 | 215.0 | 341.0 | 266.0 | 392.0 | 298.0 | 292.0 | 228.0 | 331.0 | 255.0 | 463.0 | 363.0 |
| 240.0 | 321.0 | 252.0 | 400.0 | 312.0 | 461.0 | 352.0 | 336.0 | 262.0 | 382.0 | 298.0 | 546.0 | 430.0 |
| 300.0 | 367.0 | 289.0 | 458.0 | 358.0 | 530.0 | 406.0 | 379.0 | 296.0 | 427.0 | 336.0 | 629.0 | 497.0 |
| 400.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 754.0 | 600.0 |
| 500.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 868.0 | 694.0 |
| 630.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 1005.0 | 808.0 |
| A1 Insulated conductors in conduit in a thermally insulated wall |
| B1 Insulated conductors in conduit on a wooden wall |
| C Single-core or multi-core cable on a wooden wall |
| D1 Single core or Multi-core cable in ducts in the ground |
| D2 Single core or Multi-core cables designed to be buried directly in the ground |
| F Single-core flat cables, touching in free air |
Current capacity table PVC insulation single core three phase
PVC insulation, three loaded conductors/copper or aluminium –
Conductor temperature: 70 °C, ambient temperature: 30 °C in air, 20 °C in ground
| Conductor cross-section |
|
|
|
|
|
|
|
|||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| mm² | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al |
| 1.5 | 13.5 | 0.0 | 15.5 | 0.0 | 17.5 | 0.0 | 18.0 | 0.0 | 19.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
| 2.5 | 18.0 | 14.0 | 21.0 | 16.5 | 24.0 | 18.5 | 24.0 | 18.5 | 24.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
| 4.0 | 24.0 | 18.5 | 28.0 | 22.0 | 32.0 | 25.0 | 30.0 | 24.0 | 33.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
| 6.0 | 31.0 | 24.0 | 36.0 | 28.0 | 41.0 | 32.0 | 38.0 | 30.0 | 41.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
| 10.0 | 42.0 | 32.0 | 50.0 | 39.0 | 57.0 | 44.0 | 50.0 | 39.0 | 54.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
| 16.0 | 56.0 | 43.0 | 68.0 | 53.0 | 76.0 | 59.0 | 64.0 | 50.0 | 70.0 | 53.0 | 0.0 | 0.0 | 0.0 | 0.0 |
| 25.0 | 73.0 | 57.0 | 89.0 | 70.0 | 96.0 | 73.0 | 82.0 | 64.0 | 92.0 | 69.0 | 114.0 | 87.0 | 110.0 | 84.0 |
| 35.0 | 89.0 | 70.0 | 110.0 | 86.0 | 119.0 | 90.0 | 98.0 | 77.0 | 110.0 | 83.0 | 143.0 | 109.0 | 137.0 | 105.0 |
| 50.0 | 108.0 | 84.0 | 134.0 | 104.0 | 144.0 | 110.0 | 116.0 | 91.0 | 130.0 | 99.0 | 174.0 | 133.0 | 167.0 | 128.0 |
| 70.0 | 136.0 | 107.0 | 171.0 | 133.0 | 184.0 | 140.0 | 143.0 | 112.0 | 162.0 | 122.0 | 225.0 | 173.0 | 216.0 | 166.0 |
| 95.0 | 164.0 | 129.0 | 207.0 | 161.0 | 223.0 | 170.0 | 169.0 | 132.0 | 193.0 | 148.0 | 275.0 | 212.0 | 264.0 | 203.0 |
| 120.0 | 188.0 | 149.0 | 239.0 | 186.0 | 259.0 | 197.0 | 192.0 | 150.0 | 220.0 | 169.0 | 321.0 | 247.0 | 308.0 | 237.0 |
| 150.0 | 216.0 | 170.0 | 262.0 | 204.0 | 299.0 | 227.0 | 217.0 | 169.0 | 246.0 | 189.0 | 372.0 | 287.0 | 356.0 | 274.0 |
| 185.0 | 245.0 | 194.0 | 296.0 | 230.0 | 341.0 | 259.0 | 243.0 | 190.0 | 278.0 | 214.0 | 427.0 | 330.0 | 409.0 | 315.0 |
| 240.0 | 286.0 | 227.0 | 346.0 | 269.0 | 403.0 | 305.0 | 280.0 | 218.0 | 320.0 | 250.0 | 507.0 | 392.0 | 485.0 | 375.0 |
| 300.0 | 328.0 | 261.0 | 394.0 | 306.0 | 464.0 | 351.0 | 316.0 | 247.0 | 359.0 | 282.0 | 587.0 | 455.0 | 561.0 | 434.0 |
| 400.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 689.0 | 552.0 | 656.0 | 526.0 |
| 500.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 789.0 | 640.0 | 749.0 | 610.0 |
| 630.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 905.0 | 746.0 | 855.0 | 711.0 |
| A1 Insulated conductors in conduit in a thermally insulated wall |
| B1 Insulated conductors in conduit on a wooden wall |
| C Single-core or multi-core cable on a wooden wall |
| D1 Single core or Multi-core cable in ducts in the ground |
| D2 Single core or Multi-core cables designed to be buried directly in the ground |
| F Single-core flat cables, touching in free air |
| Ft Single-core trefoil cables, touching in free air |